AKYAPAK-AHS-UserManual-2019.03.11
REVERSE BARREL ERROR
This is the condition where the center of the final form is closed and ends are open.
CAUSE 1 = the fact that plate used is very thin
REMEDY 1 = there is no other solution to this problem than using a machine with lower
performance.
CAUSE 2 = the fact that compression pressure is very weak
REMEDY 2 = slightly increase the pressure of ROLL.
CYLINDER ERROR
This error occurs when one side of the tube is more closed than the other side.
CAUSE 1 = the fact that rolls are not perfectly in parallel to each other.
REMEDY 1 = release the plate and place it on the center. If there is no progress, slightly tilt
the side rolls, thus you can minimize the error.