INSPECTION OF ELECTRIC MOTOR ROTATION DIRECTION
Operator shall check the rotation direction after the filling of the hydraulic oil is completed.
Follow the instructions below for this purpose.
FOR 380/400/415V (OTHER VOLTAGES)
These machines are equipped with phase order relay. This relay is intended to prevent
operation of electric motor in the reverse direction.
After making the electric connection, light shall illuminate in green if the phase is correct.
Replace R-S phases if the light is not illuminated.
Bring the main switch on power panel to position 1.
Bring the selector switch on control panel to position 1.
Ensure that 'Power on' is illuminated; if this light is not illuminated, check the
electrical connection, emergency stop button and safety rope.
Press start button, then press stop button and check the rotating direction of the