System Management
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 257
Basic System Configuration
This section provides information to configure system parameters and provides configuration
examples of common configuration tasks. The minimal system parameters that should be
configured are:
System Information Parameters on page 260
System Time Elements on page 263
The following example displays a basic system configuration:
A:ALA-12>config>system# info
#------------------------------------------
echo "System Configuration "
#------------------------------------------
name "ALA-12"
coordinates "Unknown"
snmp
exit
security
snmp
community "private" rwa version both
exit
exit
time
ntp
server 192.168.15.221
no shutdown
exit
sntp
shutdown
exit
zone GMT
exit
----------------------------------------------
A:ALA-12>config>system#