System Management
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 307
System Alarm Commands
config
— system
— thresholds
— cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
— no cflash-cap-alarm cflash-id
— cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
— no cflash-cap-warn cflash-id
— memory-use-alarm rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
— no memory-use-alarm
— memory-use-warn rising-threshold threshold [falling-threshold threshold] interval
seconds [rmon-event-type] [startup-alarm alarm-type]
— no memory-use-warn
— [no] rmon
— alarm rmon-alarm-id variable-oid oid-string interval seconds [sample-type]
[startup-alarm alarm-type] [rising-event rmon-event-id rising-threshold
threshold] [falling event rmon-event-id falling-threshold threshold] [owner
owner-string]
— no alarm rmon-alarm-id
— event rmon-event-id [event-type] [description description-string] [owner
owner-string]
— no event rmon-event-id