System Alarm Commands
Page 342   7210 SAS M, T, X, R6 Basic System Configuration 
Guide
falling-threshold threshold — Specifies a threshold for the sampled statistic.  When the current 
sampled value is less than or equal to this threshold, and the value at the last sampling interval 
was greater than this threshold, a single threshold crossing event will be generated.  A single 
threshold crossing event will also be generated if the first sample taken is less than or equal to 
this threshold and the associated ’startup-alarm’ is equal to ’falling’ or ’either’.
After a rising threshold crossing event is generated, another such event will not be generated 
until the sampled value rises above this threshold and reaches greater than or equal the rising-
threshold threshold value.
Default 0
Values -2147483648 — 2147483647
owner owner  — The owner identifies the creator of this alarm.  It defaults to "TiMOS CLI".  This 
parameter is defined primarily to allow entries that have been created in the RMON-MIB 
alarmTable by remote SNMP managers to be saved and reloaded in a CLI configuration file.  The 
owner will not normally be configured by CLI users and can be a maximum of 80 characters 
long.
Default TiMOS CLI
Configuration example:
alarm 3 variable-oid ifInOctets.184582144 interval 20 sample-type delta start-alarm 
either rising-event 5 rising-threshold 10000 falling-event 5 falling-threshold 9000 
owner "TiMOS CLI"
cflash-cap-alarm
Syntax cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold] 
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context config>system>thresholds
Description This command enables capacity monitoring of the compact flash specified in this command. The 
severity level is alarm. Both a rising and falling threshold can be specified. 
The no form of this command removes the configured compact flash threshold alarm.
Parameters cflash-id  — The cflash-id specifies the  name of the cflash device to be monitored.
Values cf1:, cf2 (only on 7210 SAS-T), cf1-A:
rising-threshold threshold — Specifies a threshold for the sampled statistic.  When the current 
sampled value is greater than or equal to this threshold, and the value at the last sampling interval 
was less than this threshold, a single threshold crossing event will be generated.  A single 
threshold crossing event will also be generated if the first sample taken is greater than or equal to 
this threshold and the associated ’startup-alarm’ is equal to ’rising’ or ’either’.