System Management
7210 SAS M, T, X, R6 Basic System Configuration Guide Page 239
ref-order ptp [Must be configured]
config> system> sync-if-timing> commit
Note: Now the Frequency and Time is provide by PTP [configure >system >ptp >no shutdown]
only. This is a standalone PTP mode.
Example configuration on use of PTP and syncE references on
7210 SAS-T
The configuration example for 7210 SAS-T showing use of PTP and syncE references
simultaneously is as below:
*A:SAS-T-B>config>system>sync-if-timing# info detail
----------------------------------------------
ql-selection
ref-order ptp ref1 ref2 --> All three reference can be configured simultaneously
ref1
source-port 1/1/1
no shutdown
no ql-override
exit
ref2
source-port 1/1/7
no shutdown
no ql-override
exit
ptp
no ql-override
no shutdown
exit
revert
----------------------------------------------