System Alarm Commands
Page 344 7210 SAS M, T, X, R6 Basic System Configuration
Guide
cflash-cap-alarm cf1-A: rising-threshold 50000000 falling-threshold 49999900 interval 120
rmon-event-type both start-alarm rising.
cflash-cap-warn
Syntax cflash-cap-warn cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-warn cflash-id
Context config>system>thresholds
Description This command enables capacity monitoring of the compact flash specified in this command. The
severity level is warning. Both a rising and falling threshold can be specified. The no form of this
command removes the configured compact flash threshold warning.
Parameters cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
Values cf1:, cf2 (only on 7210 SAS-T), cf1-A:
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated startup-alarm is equal to rising or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value falls below this threshold and reaches less than or equal the falling-
threshold value.
Default 0
Values -2147483648 — 2147483647
falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated startup-alarm is equal to falling or either.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value raises above this threshold and reaches greater than or equal the rising-
threshold value.
Default 0
Values -2147483648 — 2147483647
interval seconds — Specifies the polling period over which the data is sampled and compared with
the rising and falling thresholds.
Values 1 — 2147483647
rmon-event-type — Specifies the type of notification action to be taken when this event occurs.

Table of Contents

Other manuals for Alcatel-Lucent 7210 SAS M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS M and is the answer not in the manual?

Alcatel-Lucent 7210 SAS M Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS M
CategorySwitch
LanguageEnglish

Related product manuals