126 Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Chapter 4 Bulletin 290E/291E/294E Programmable Parameters
StarterCommand
The parameter provides the command
status of the starter.
Parameter Number 7
Access Rule GET
Data Type WORD
Group Basic Status
Units
Minimum Value 0
Maximum Value 0xFF1F
Default Value 0
Bit
Function
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
——————————————— X RunningForward
—————————————— X RunningReverse
————————————— X —— ResetFault
———————————— X ——— JogForward
——————————— X ———— JogReverse
———————— X X X ————— Reserved
——————— X ———————— Out00
—————— X ————————— Out01
————— X —————————— Out02
———— X —————————— Out03
——— X ———————————— Out04
—— X ————————————— Out05
X —————————————— Accel2
X ——————————————— Decel2
AuxIOStatus
Status of the hardware
input/output points.
Parameter Number 8
Access Rule GET
Data Type WORD
Group Basic Status
Units
Minimum Value 0
Maximum Value 0x3F
Default Value 0