The Drain Sequence
Drain
Extract
No Drain
Static Drain
Reversing Drain
The Drain Sequence
Display Mes-
sage Default Information Limits
Drain Valve 1 Only available on washing machines with both: a normal Open and
normal Closed Drain valve.
1 - 2
Time 0.5 minutes The Drain Sequence Time.
(for 0 Minutes the Drain sequence will be skipped)
(programmable in steps of 0.5 Minutes)
0 - 15.0 minutes
Exit Return to Edit Program Menu.
Table 32
The Extract Sequence
Drain
Extract
No Drain
Static Drain
Reversing Drain
The Extract Sequence
Display Mes-
sage Default Information Limits
Drain Valve 1 Only available on washing machines with both : a normal Open and
normal Closed Drain valve.
1 - 2
RPM - The suggested RPM depends on the machine Type. Refer to Table 7
Time 9 minutes The Extract Sequence Time.
(for 0 Minutes the Extract sequence will be skipped) (programmable
in steps of 0.5 Minutes)
0 - 15.0 minutes
Exit Return to Edit Program Menu.
Table 33