Faults Menu (Service Faults)
Display Message Information
View Fault Statist …
1 No Drain 0x
The Fault Statistics are an accumulation of Error messages that have ap-
peared over a long period. With this information the technician has an indica-
tion on which parts an intervention should be needed.
(the statistics are reset by the "Reset Service Counts" menu item in the tool-
box menu)
The List with Statistics :
No Drain : E2 + E37
Door Switch : E6 + E7 + E8 + E9
No Fill : E11 + E40
No Heating : E13 + E14
Temp Sensor : E25
Level Sensor : E24
Safety switch : E3
Invert Com : E27
Invert Alarm : E26 + E28 + E29 + E72 + E73 + E74 + E75
Invert OV Alarm : E303 + E304 + E305
Table 54
Toolbox Menu
The purpose of the Toolbox Menu is to give support at technical
interventions.
Toolbox Menu
Display Message Information
View Input States ?
1 Input 1 On
20 Input 20 Off
The Input states for Input 1, …, Input 20.
The exact function of the inputs can be found on the electrical drawing of the
washing machine programmer.
If the Input state is Off, the Input signal is low.
If the input state is On, the Input signal is high.