Diagnostic Test Sequence
Test Information Explanation
Unload End of the Diagnostic Cycle
* The second drain valve will be opened if a second drain valve has been selected in the Configuration menu.
** No number 2 is displayed at the sensor test as this takes only a fraction of a second.
If ++ ++ is displayed at the motor test sequence, then you can Advance (Press START) the test Sequence.
Table 56
Basic Diagnostic Wash Program
Error Messages
• If the computer detects some problem during the Diagnostic
Help Program, a diagnostic error message is generated.
• Check also the Error Log List in the Service Menu.
• Check the error handling and explanation of the error messag-
es.
Basic Diagnostic Wash Program
Sequence Supply Inlet
Tem-
pera-
ture Level
Wash Ac-
tion Time
R.P.M
.Top Front Top Front Top Front
Step 1 Wash Wash B 2=30
seconds
3-4-5 2-3-6-8 104°F
[40°C]
NL A=12 seconds
R=3 seconds
6 mi-
nutes
W
Drain Drain - - - - - - - 30 sec-
onds
D
Step 2 Rinse 1 Rinse 1 - - 2-5-6 1-2-7 - NH A=12 seconds
R=3 seconds
1.5 mi-
nutes
W
Spin Spin - - - - - - - 1 minute L
Step 3 Final
Rinse
Rinse 2 C 3=30
seconds
1(+6) 4-7 - NL A=12 seconds
R=3 seconds
2 mi-
nutes
W
Spin Spin - - - - - - - 4.5 mi-
nutes
H
Slowdown - - - - - - 1 minute -
Tumble - - - - - A=12 seconds
R=3 seconds
30 sec-
onds
W
Table 57
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
90 Part No. D1676ENR11