EasyManua.ls Logo

ALLIANCE SCL020WT - Door Lock Non-Fatal Error E Dl1 (1 of 2)

ALLIANCE SCL020WT
157 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Door Lock Non-Fatal Error E dL1 (1 of 2)
Is door handle fully
engaged?
Is the solenoid
mechanically bound?
Yes
Fully latch door.
No
Is the door closed
LED on DR LED?
No
Adjust/replace
solenoid as necessary.
Yes
Did the solenoid lock
the door?
Yes
See Door Close Error
section.
No
(A)
Power down the
machine. Disconnect
connector to H7 on
AP1. At the harness
end measure the
resistance between
H7-3 and H7-4. Is the
resistance 2.9 ohms
+/- 5%?
No
Continue to 2 of 2.
Yes
(B)
Is the resistance 2.9
ohms +/- 5% when
measure at the
solenoid?
No
Replace AP1.
Yes
Inspect harness.
Replace harness as
needed.
Yes
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -