Alarm Fault Remedy Notes
H2O
No water in chamber, or water
pressure too low.
Check that mains water is pre-
sent or adjust the pressure (see
“installation manual”); if the
problem persists inform the
after-sales service.
Convection cooking cycles can
still be carried out.
H2O.
No water at drain, or water
pressure too low.
Check that mains water is pre-
sen, if the problem persists
inform the after-sales service.
Convection and steam coo-
king cycles can still be carried
out
H2OL
There is no water in the cham-
ber or there is insu cient wa-
ter pressure during washing.
Check that mains water is pre-
sent; if the problem persists in-
form the after-sales service.
Cooking cycles can be carried
out.
H2OL.
There is no drain water, or
there is insu cient water pres-
sure during washing.
Check that mains water is pre-
sent; if the problem persists in-
form the after-sales service.
It is not possible to run cook-
ing cycles until an entire wash
cycle or emergency rinse has
been carried out.
OPE
Oven door opening or closure
request.
Open or close the oven door
Inform the after-sales service
if this message continues to be
displayed.
The cooking cycle does not
start until the door has been
opened or closed as required.
CLE
At oven switch-on: Indicates
that cleaning is required.
Perform a washing program.
Normal operation of the oven
depends on the “Oven clean-
ing time limit OFF/ON” setting.
CAL
At oven switch-on: Indicates
the need for the descaling op-
eration.
Perform descaling.
The ovens functions are ena-
bled so cooking cycles can be
carried out.
E01
The cooking chamber probe
has failed or is not properly
connected.
Inform the after-sales service.
The ovens functions are disa-
bled so no cooking cycles can
be carried out.
E02
The product core probe is not
inserted in the food or has
failed.
Check the position of the pro-
duct core probe or inform the
after-sales service if it is faulty.
Cooking cycles with product
core probe cannot be carried
out.
E03
The steam discharge probe
has failed.
Inform the after-sales service.
Convection and steam cook-
ing cycles can still be carried
out.
E04
The motor-operated valve is
not positioned correctly.
Switch on the oven again and
if the problem persists inform
the after-sales service.
Convection and steam coo-
king cycles can still be carried
out.
E05 Safety thermostat failure. Inform the after-sales service.
The ovens functions are disa-
bled so no cooking cycles can
be carried out.
E06 Overload cutouts tripped. Inform the after-sales service.
The ovens functions are disa-
bled so no cooking cycles can
be carried out.
E07 Power board failure Inform the after-sales service.
The ovens functions are disa-
bled so no cooking cycles can
be carried out.
E08
The optional vacuum probe
has failed or is not properly
connected.
Press “RESET.
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service.
E09
Maximum allowed tempera-
ture in chamber exceeded
I
nform the after-sales service
The ovens functions are disa-
bled so no cooking cycles can
be carried out