10.2 Command Set 73
Response: >900WD:yy-mm-dd hh:mm:ss.fff:cc< CR >
yy-mm-dd the current date:
yy = year of century, (00. . . 99)
mm = month, (1. . . 12)
dd = day of month, (01. . . 31)
= Space (ASCII 20h)
hh:mm:ss.fff the current time:
hh = hours, (00. . . 23)
mm = minutes, (00. . . 59)
ss = seconds, (00. . . 59, or 60 while leap second)
fff = milliseconds, (000. . . 999)
cc = Check sum*
< CR > = Carriage Return (ASCII code 0Dh)
*EXCLUSIVE-OR result of previous characters, displayed as HEX byte (2 ASCII characters 0. . . 9
or A. . . F)
Broadcast PATEK PHILIPPE MSG (CUSTOM 1)
Command: BA, OA
BA configures the clock to broadcast the Patek Philippe message (or CUSTOM 1) from the main
RS-232 port. OA configures the clock to broadcast the Patek Philippe message from the Option
RS-232 port.
Response: T:yy:mm:dd:dw:hh:mm:ss
C
Where: dw = day of week
Broadcast KISSIMMEE MSG
Command: 1,nTB
1,nTB configures the clock to broadcast the Kissimmee message (Telegyr 5700) from the main
RS-232 port, where n = the time zone; time reported is in UTC format for n = 0, and Local for n
= 1.
Response: ddd:hh:mm:ssQ
C
Where: Q = quality indicator (with indicators shown below)
= locked, maximum accuracy
. = (ASCII 46) Error < 1 microsecond
* = (ASCII 42) Error < 10 microseconds
# = (ASCII 35) Error < 100 microseconds
? = (ASCII 63) Error > 100 microseconds
Pin 6 Serial Port Broadcast Control
Command: xPM