EasyManuals Logo

Balluff BVS HS-P Series User Manual

Balluff BVS HS-P Series
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #122 background imageLoading...
Page #122 background image
122
3
Configuration Using Barcodes
Balluff BVS HS-P Family
Industrial Handheld Barcode Readers
Code 128 Set
Length 2
This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the barcode’s data characters only.
The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only
one fixed length).
Table Code 128 Length 2 Setting Examples provides examples for setting Length 2. See
page 250 for detailed instructions on setting this feature.
Code 128
Length 2 Setting
Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore
This Length)
07
Characters
15
Characters
80
Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 128 LENGTH 2 SETTING
4
Scan Two Characters
From Appendix D:
Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘8’ and 0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You
can then start again at the beginning.
CANCEL
$CC8L2
~
DEFAULT
80 = Length 2 is 80 Characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Balluff BVS HS-P Series and is the answer not in the manual?

Balluff BVS HS-P Series Specifications

General IconGeneral
BrandBalluff
ModelBVS HS-P Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals