July 25, 2023
Q5X With Dual Discrete Outputs And IO-Link Instruction Manual
20
•
•
•
•
•
•
•
•
•
2000 mm Models
ResponseSpeed ResponseSpeedinSyncMode Repeatability AmbientLightRejection ExcessGain
3ms 6ms 1000µs Disabled
SeeExcessGainin"Q5XDualDis
crete with IO-Link Specifications" on
page 39
5ms 10ms 1600µs Enabled
15ms 30ms 3ms Enabled
25ms 50ms 5ms Enabled
50ms 100ms 10ms Enabled
5000 mm and 10000 mm Models
ResponseSpeed ResponseSpeedinSyncMode ExcessGain
2ms 4ms
SeeExcessGainin"Q5XDualDiscretewithIOLinkSpec
ifications" on page 39
5ms 10ms
15ms 30ms
50ms 100ms
250ms 500ms
Gain and Sensitivity (GAin)
Usethismenutosettheexcessgainmode.
For2000mmmodels—Thismenuisonlyavailablewhena15,25,or50millisecondresponsespeedisselected.Itisnot
available for 3 or 5-millisecond response speeds.
—Highexcessgainmode
—Standardexcessgainmodewithincreasednoiseimmunity
For5000mmmodels—
—Performancegainmodeprovidesthebestperformanceonthetypicalrangeofdarktoshinytargets
—Blackgainmodeprovidesthemaximumexcessgainandbestperformancewhenlookingatextremelydark
targetswithlittlereflectivity
—Shinygainmodeprovidesthebestperformancewhenlookingatextremelyreflectivesurfaces.
Output Timing Delays
Usethismenutoselecttheoutputtimingdelaytobeset.
Onandoffdelaytimerscanbeusedtogether.Thedefaultisnodelay.For Channel 2, this menu is available when the output
is set to light operate or dark operate.
NOTE: ThenumberthatfollowsdLYonthedisplayindicateswhichchannelisselected.
—Nodelay
—Delay—enablestheselectionofonandoffdelaytimers
—Oneshot—enablesaoneshot,fixedoutputpulseduration
—Totalizer—enablesanoutputafteradefinednumberoftargetsarecounted
© Banner Engineering Corp.