Q5X With Dual Discrete Outputs And IO-Link Instruction Manual
28
•
•
•
ResettoFactoryDefaultsUsingtheRemoteInput
FollowtheinstructionsbelowtoresettheQ5XtofactorydefaultsusingRemoteInput.
EightpulsetheremoteinputtoapplythefactorydefaultsandreturntoRunmode.
The input wire function remains at remote teach input (SEt).
Locking and Unlocking the Sensor Buttons
Usethelockandunlockfeaturetopreventunauthorizedoraccidentalprogrammingchanges.
Three settings are available:
—Thesensorisunlockedandallsettingscanbemodified(default).
—Thesensorislockedandnochangescanbemade.
—Theswitchpointvaluecanbechangedbyteachingormanualadjustment,butnosensorsettingscanbe
changedthroughthemenu.
WhenthesensorisineitherLocor0Locmode,theactivechannelcanbechangedusing(+)(CH1/CH2).
WheninLocmode,Locdisplayswhenthe(SELECT)(TEACH)buttonispressed.Theswitchpointdisplayswhen(+)(CH1/
CH2)or(-)(MODE)arepressed,butLocdisplaysifthebuttonsarepressedandheld.
Whenin0Locmode,Locdisplayswhen(-)(MODE)ispressedandheld.Toaccessthemanualadjustoptions,brieflypress
andrelease(+)(CH1/CH2)or(-)(MODE).ToenterTEACHmode,pressthe(SELECT)(TEACH)buttonandholdforlonger
than2seconds.
Button Instructions
To enter Loc mode, hold + and press - four times. To enter 0Loc mode, hold + and press - seven times. Holding + and press
ing - four times unlocks the sensor from either lock mode and the sensor displays uLoc.
Remote Input Instructions
Continued from page 27
Action
Result
Pulses TEACHMode
5
Dual(intensity+distance)
Access the remote input.
Action Result
Fourpulse the remote input.
The sensor is ready to have the button state
defined and btn displays.
Lock or unlock the sensor buttons.
Action Result
Singlepulse the remote input to unlock the sensor.
uLoc displays and the sensor returns to
Run mode.
Continued on page 29