AW00123409000 Features
Basler ace USB 3.0 225
7.7.3.2 Carrying Out Configuration
Carry out the following routine for each sequencer set you want to configure.
1. Make sure the value of the Sequencer Mode is set to Off.
2. Make sure the value of the Sequencer Configuration Mode is set to On.
3. To configure the desired sequencer set, select its index number.
4. Set the camera parameter values as desired.
5. Set the sequencer set-related parameter values for path 0.
6. Set the sequencer set-related parameter values for path 1.
Note: The following step will replace any previous parameter settings for the selected se-
quencer set.
7. Store the sequencer set with its changed parameter values.
The sequencer set is available for use by the sequencer feature with new parameter values.
You can configure the sequencer and sequencer sets from within your application software by using
the Basler pylon API. The following code snippet illustrates configuring the parameters for
sequencer start and for sequencer set 0, and storing sequencer set 0 using the API to set the
parameter values.
The example assumes that you have already set the current camera parameter values as desired
for sequencer set 0. The example assumes that you are setting the parameter values for sequencer
set 0 as given in Figure 87 on page 218 and Table 50 on page 231.
Before configuring sequencer sets: Make sure the sequencer mode is set to Off
and the sequencer configuration mode is set to On.
Otherwise the parameter values of the current sequencer set cannot be read or
changed using the pylon API or the pylon Viewer. Only those sequencer set
parameter values will be displayed that were active before the sequencer mode
was set to On.
You will not be able to "see" the new parameter values set for the current
sequencer set.
We recommend that you do not attempt to read or change any of the sequencer
parameters when the sequencer mode is set to On.
It may occur that you will not configure all parameter values used with a sequencer
set (see Section 7.7.2 on page 217). In these cases, the previous parameter
values will persist in the active set.
To configure and store a sequencer set: