AW00123409000 Physical Interface
Basler ace USB 3.0 71
5.6 Camera Power
Camera power must be supplied to the camera via the USB 3.0 cable plugged into the camera’s
USB 3.0 Micro-B port.
Note that direct-coupled GPIO lines have the advantage of working with very short
delays compared to opto-isolated I/O lines.
Note also that the direct-coupled GPIOs are distinctly more susceptible to EMI
than the opto-isolated I/Os. Under harsh EMI conditions, GPIOs can turn out not
to be usable at all.
Accordingly, use of the GPIOs in an environment with elevated risk of EMI calls for
taking additional measures like, e.g. using shorter cables.
DANGER
Electric Shock Hazard
Risk of Burn or Death.
The power supply used for supplying camera power must meet the Safety Extra
Low Voltage (SELV) and Limited Power Source (LPS) requirements.
If you use a powered hub as part of the USB 3.0 connection, the powered hub
must meet the SELV and LPS requirements.
WARNING
Fire Hazard
Risk of Burn
The power supply used for supplying camera power must meet the Limited Power
Source (LPS) requirements.
A suitable power supply is available from Basler. Contact your Basler sales
representative to order a power supply.
If you use a powered hub as part of the USB 3.0 connection, the powered hub
must meet the LPS requirements.