Features AW00123409000
306 Basler ace USB 3.0
camera.AutoExposureTimeUpperLimit.SetValue(500000.0);
// Set the target gray value for the selected auto function
// The parameter value range refers to the theoretically maximum
// available range of gray values for the set pixel format.
// For example, if an 8 bit pixel format is set, a parameter value
// of 0.50196 will correspond to a gray value of 128.
camera.AutoTargetBrightness.SetValue(0.50196);
// Set the mode of operation for the exposure auto function
camera.ExposureAuto.SetValue(ExposureAuto_Continuous);
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 3.1 on page 61.
For general information about auto functions, see Section 7.15 on page 294.
For information about Auto Function ROIs and how to set them, see Section 7.15.3 on page 296.
For information about minimum allowed and maximum possible exposure time, see Section 6.9 on
page 174.