Features AW00123409000
328 Basler ace USB 3.0
The User Sets with Factory Setups
When a camera is manufactured, numerous tests are performed on the camera and three factory
optimized setups are determined. The three user sets with factory optimized setups are:
The Default User Set with a standard factory setup that is optimized for average conditions and
will provide good camera performance in many common applications. In the standard factory
setup, the gain is set to a low value, and all auto functions are set to off.
The High Gain User Set is similar to the Default User Set, but the gain is set to + 6 dB.
The Auto Functions User Set is similar to the Default User Set, but the Gain Auto and the
Exposure Auto auto functions are both enabled and are set to the continuous mode of
operation. During automatic parameter adjustment, gain will be kept to a minimum.
The Color Raw User Set is available in some color cameras. The user set is similar to the
Default User Set, but no color enhancement feature is active.
The user sets with factory setups are saved in permanent files in the camera’s non-volatile memory.
They are not lost when the camera is reset or switched off and they can not be changed.
For more information about auto functions, see Section 7.15 on page 294.
For more information about color enhancement features, see Section 7.14.3 on page 278.
The User Set Default
You can designate one of the six user sets (the Default User Set, High Gain User Set, Auto
Functions User Set, User Set 1, User Set 2, User Set 3) as the User Set Default, i.e. as the startup
user set. The startup user set will automatically be loaded into the active set whenever the camera
starts up at power on or after a reset. Instructions for designating a user set as the User Set Default
appear below.
The values for sequencer sets can not be saved in any user set.
The values for the luminance lookup table are not saved in any user set and
are lost when the camera is reset or switched off. If you are using the lookup
table feature, you must reenter the lookup table values after each camera
startup or reset.
The current luminance lookup table is not changed when a user set is loaded
into the active user set.