Loading...
Connection
cross section
Connection
method
Load capacity
X207
Motor temperature
an
d brake motor 1
BM5323
BM5325
BM5331
BM5332
BM5333
Max. 1.0 mm² Plug connector,
spr
ing-clamp
connection
Max. 2 A
BM5326
BM5327
BM5328
BM5334
BM5335
Max. 4 A
BM537X Max. 1.5 mm² Max. 8 A
X208
Motor temperature
an
d brake motor 2
BM5323
BM5325
BM5331
BM5332
BM5333
Max. 1.0 mm² Plug connector,
spr
ing-clamp
connection
Max. 2 A
NOTE!
A relay with varistor protection circuit is required in case the customer connects an
ad
ditional relay.
Installation
Instruction handbook b maXX 5000
Document No.: 5.09021.16