Connections on the front side
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
194
of 328
7.15
Encoder
evaluation with
En
Dat
®
2.2
The encoders, which meet the following te
chnical specifications, can be used:
Voltage supply 5 V
DC
controlled
Signal level ~1 V
SS
Current input Max. 250 mA
D-sub-connector
26-pin
1 GND encoder supply
2 +5 V encoder supply
3 Clock+
4 re
served *
5 re
served *
6 re
served *
7 re
served *
8 re
served *
9 re
served *
10 re
served *
11 Sense GND
12 Sense Vcc
13 Clock-
14 re
served *
15 re
served *
16 re
served *
17 re
served *
18 re
served *
19 Dat
a +
20 Dat
a -
21 re
served *
22 re
served *
23 re
served *
24 re
served *
25 re
served *
26 re
served *
* do not occupy