Installation
Instruction handbook b maXX 5000
Document No.: 5.09021.16
195
of 328
7
Sine or square
wave
encoder evalua-
tion
The encoders, which meet the following technical specifications, can be used:
Voltage supply 5 V
DC
controlled
Signal level RS422 (TTL) for square wave incremental encoders
~1 Vss for sine incremental encoders
Current input Max. 250 mA
D-sub-connector
26-pin
1 GND encoder supply
2 +5 V encoder supply
3 re
served *
4 RS4
22 A +
5 RS4
22 A -
6 RS4
22 B +
7 RS4
22 B -
8 RS4
22 0 +
9 RS4
22 0 -
10 re
served *
11 Sense GND
12 Sense V
CC
13 reserved *
14 re
served *
15 re
served *
16 re
served *
17 T
emperature +
18 T
emperature -
19 re
served *
20 re
served *
21 re
served *
22 re
served *
21 re
served *
22 re
served *
23 re
served *
24 re
served *
25 re
served *
26 re
served *
* do not occupy