42
925.916.2 - GBINSTRUCTIONS PERTAINING TO THE USER
- press either of the keys to access the programming function;
- press these keys until the display shows P5, referring to the temperature to be set;
- press the
keys to set the temperature required.
This operating mode is enabled when minimum temperature central heating mode is activated or when the daily central
heating program does not require heat.
NOTE With the outdoor sensor probe connected, parameter P5 can be used to set the minimum room tempe-
rature in the premises to be heated.
3.6 –
settIng the mInImum Central heatIng temperature
3.7 –
table of user-settable parameters
Range
0…23:59
25..80
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
00:00…24:00
0...1
Factory
setting
———-
25
6:00
22:00
0:00
0:00
0:00
0:00
0:00
24:00
0:00
0:00
0:00
0:00
0
Parameter description
Time of day setting
Minimum central heating temperature setting (°C)
Start of rst daily period of automatic central heating
End of rst daily period of automatic central heating
Start of second daily period of automatic central heating
End of second daily period of automatic central heating
Start of third daily period of automatic heating
End of third daily period of automatic central heating
Start of rst daily period of domestic hot water production
End of rst daily period of domestic hot water production
Start of second daily period of domestic hot water production
End of second daily period of domestic hot water production
Start of third daily period of domestic hot water production
Fine End of third daily period of domestic hot water production
Reset of daily central heating and domestic hot water production programs (factory
settings). Press the - + keys together for about 3 seconds; the number 1 appears
on the display. Conrm by pressing either of the
Parameter
N.
P1
P5
P11
P12
P13
P14
P15
P16
P31
P32
P33
P34
P35
P36
P45
NOTE – Parameters from P31 to P36 can be displayed only if the domestic hot water program has been enabled as
described in chapter 17 for the attention of the installer (parameter H91).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi LUNA3 SYSTEM HT 1.180 MP and is the answer not in the manual?

Baxi LUNA3 SYSTEM HT 1.180 MP Specifications

General IconGeneral
BrandBaxi
ModelLUNA3 SYSTEM HT 1.180 MP
CategoryHeat Pump
LanguageEnglish

Related product manuals