Compile Error Messages
Validation of the Topology Map
Message
: The Automatic Mixer (object code '__') at [__,__] has no active audio output.
Explanation
: An Auto Mixer Main Output is connected to a Mix-Minus Combiner
input, but appropriate audio output connections have not been made.
Mix-Minus Combiners allow Auto Mixers to share
control data only, and do not support audio input or output.
Message
: Unintended use of Combiner block detected.
Explanation
: A source, other than an Auto Mixer Main Output, is connected to a
Mix-Minus Combiner input. Mix-Minus Combiners allow Auto Mixers to share
control data only, and do not support audio input or output.
Message
: The main output of an Auto Mixer is connected to more than one
Combiner block.
Explanation
: The main output of an Auto Mixer can be connected to only a single
Combiner input (Mix-Minus or Room). Otherwise, Auto Mixer control
data might be shared with multiple groups of combined mixers, causing
convoluted behavior.
Messages
: Incomplete signal path for Telephone Interface Receive block
(object code '__') at [__,__].
Incomplete signal path for Telephone Interface Transmit block
(object code '__') at [__,__].
Explanation
: Each functional Telephone Interface (TI-2 card channel) must have both
the Receive and the Transmit blocks properly connected.
Message
: Empty layout !
Explanation
: No objects have been placed in the layout.