Display Options
Allows DSP Blocks (Component Objects) to display Device Assignment or Group Assignment numbers, as
determined by Compile. (Device Assignments can be changed in the Property Sheet.) A third option is to
display DSP Resource Requirements, which indicates the block's DSP usage as a percentage of total DSP
resources available within a single hardware unit. Allows color of Signal Path Identifier to be changed.
Allows CobraNetâ„¢ Connections to be displayed, and color to be changed (see System Network
Considerations). Allows the default Grid to be applied when starting new design files.