108
Setting up the Audia units after a successful compilation
Message
: Could not assign audio I/O channels in the unit # __.
Explanation
: Indicates a software problem. Please contact Biamp Systems.
Messages
: Available range of Instance IDs is nearly exhausted.
Range of Instance IDs has been exhausted.
Explanation
: The total number of Instance IDs, as assigned to component and
line objects, is limited to 65,535. When component objects are
removed from a design, their Instance IDs are not automatically
re-assigned to new component objects. Therefore, the messages
above indicate that a significant number of Instance IDs has been
wasted. Set 'Reassign Instance IDs' under Tools>Options>Compile
and re-compile to recover wasted Instance IDs. CAUTION: This
will change most component Instance IDs, and will render existing
external control command scripts useless. Once Instance IDs have
been recovered, turn off 'Reassign Instance IDs' to avoid further
re-assignments.
Message
: I/O channel assignment in the unit # __ is inconsistent with factory
hardware configuration.
Explanation
: AudiaFLEX units leave the factory with I/O cards arranged in specific
order, with input cards starting on the right (when viewing the rear panel),
and output cards starting on the left. If the Compiler encounters an I/O
channel number assignment fixed to a unit (through fixed allocation of the
I/O DSP block), which is inconsistent with the factory numbering scheme,
this warning will be given.