CB (E7) 06/2018 Page 162/174
Regular equipment (continued)
Permadry™ humidity system
Weldless deep-drawn polished inner chamber made of stainless steel 1.4301/V2A, polished
FailSafe – Electronic error auto-diagnosis system with zero-voltage relay output
Zero-voltage relay alarm output with DIN socket (6 poles), DIN plug included
Tightly closing inner glass door
3 perforated shelves, stainless steel 1.4301/V2A
Overtemperature safety controller class 3.1 acc. to DIN 12880:2007
Chamber with active humidification: Microprocessor controlled humidifying system
Chamber with O
2
control: O
2
control in the hypoxic control range 0.2 to 20 vol. % O
2
.
Ethernet interface for computer communication
Perforated shelf ,stainless steel
Chamber with O
2
control: Alternative control range 10 to 95 vol. % O
2
(available via BINDER
INDIVIDUAL Customized Solutions)
Freshwater bag (0.9 liters / 0.32 cu.ft.)
Divided inner door, gas-proof, stainless steel, 4 times (CB 56), 6 times (CB 170), 8 times (CB 260)
Shelves for divided inner door, gas-proof, stainless steel
Stacking stand with castors lockable by breaks (CB 170 / CB 210)
Stacking adapter for direct, thermally decoupled stacking
Stacking adapter for combination C 150 on top of CB 170
Silicone access ports closable with 2 silicone plugs
BINDER Gas Supply Service: External CO
2
bottle changer CO
2
, O
2
or N
2
Connection kit for CO
2
, O
2
or
N
2
cylinder
Water tight internal socket 230 V (max. 3 A), with turn-off switch (available via BINDER INDIVIDUAL
Customized Solutions)
Analog output temperature and CO
2
4-20 mA 4-20mA with DIN socket (6 poles), DIN plug included
BINDER Data Logger kit for temperature: T 220 (chamber values), and for temperature / humidity: TH 70
(chamber values) or TH 70/70 (chamber and ambient values)
Cartridge for BINDER Pure Aqua Service
Cleaning kit (neutral cleaning agent, disinfection spray and lint-free disposable wipes, gloves and
goggles)
Intelligent Fail-Safe CO
2
monitoring function
CELLROLL roller system with set of connection cables for extra-low voltage access port
Access port (8-pin) for extra-low voltage (ELV) with LEMO socket (can be covered) and LEMO
connector, maximum power rating 24VAC/DC – 2.5 Amp
Calibration of temperature including certificate
Calibration of CO
2
including certificate
Spatial temperature measurement including certificate
Spatial temperature measurement acc. to DIN 12880 including certificate
Chamber with O
2
control: Calibration of O
2
including certificate
Chamber with active humidification: Calibration of humidity including certificate
Chamber with active humidification: Spatial temperature and humidity measurement including certificate