System Menu 53
Item Parameter MR160120 MR3K160120 MR25080 MR50040 MR100020
Output
Voltage 10 10 10 10 10
Current 1 1 1 1 1
State OFF OFF OFF OFF OFF
Protection
OVP Voltage 176 176 275 550 1100
OCP Current 144 144 96 48 24
OPP Power 5200.5 3120 5200.5 5200.5 5200.5
CV to CC OFF OFF OFF OFF OFF
CC to CV OFF OFF OFF OFF OFF
Limit
Vmax 163.2 163.2 255 510 1020
Vmin 0 0 0 0 0
Imax 122.4 122.4 81.6 40.8 20.4
Imin 0 0 0 0 0
Slope
Voltage Slope 5.33 5.33 8.33 16.67 33.33
Current Slope 1000 1000 1000 1000 1000
Beep Mode ON ON ON ON ON
Timer
Mode OFF OFF OFF OFF OFF
HHH:MM:SS 0:00:00 0:00:00 0:00:00 0:00:00 0:00:00
Program
Mode OFF OFF OFF OFF OFF
Program Number 0 0 0 0 0
Parallel
Mode OFF OFF OFF OFF OFF
Address Master Master Master Master Master
PV Simulation
Mode OFF OFF OFF OFF OFF
Curve 1 1 1 1 1
Control Mode CC CC CC CC CC
External Control
Mode EXT_V EXT_V EXT_V EXT_V EXT_V
Range 10V/10K 10V/10K 10V/10K 10V/10K 10V/10K
Shut O Live Live Live Live Live
Power-on State
Mode Disable Disable Disable Disable Disable
MEM 1 1 1 1 1
Output State O O O O O
GPIB Address 1 1 1 1 1
RS-232C Baud 9600 9600 9600 9600 9600
RS-485 Baud 9600 9600 9600 9600 9600
LAN
Mode DHCP DHCP DHCP DHCP DHCP
IP address 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
Mask address 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
Gateway address 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0 0.0.0.0
DNS 8.8.8.8 8.8.8.8 8.8.8.8 8.8.8.8 8.8.8.8
Table 8.2 Factory Default Settings