EasyManua.ls Logo

Boeing 787-8 - Page 1027

Boeing 787-8
1562 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
787 Flight Crew Operations Manual
DO NOT USE FOR FLIGHT
Flight Instruments, Displays -
Electronic Checklist Description
Copyright © The Boeing Company. See title page for details.
D615Z003-TBC 10.60.9
Approach Alert - Occurs if the approach checklist is not complete, the
airplane descends through the FMC transition level, and flaps are not in
UP.
Landing Alert - Occurs if the LANDING checklist is not complete, and the
airplane descends below 500 feet above the FMC landing runway.
When an alert condition occurs, the EICAS caution message CHKL
INCOMPLETE NORM is displayed. The message remains displayed until the
respective checklist is completed or overridden. A rectangular checklist icon is
displayed with the CHKL INCOMPLETE NORM message as a reminder to the
crew to select ECL, even though there is no non-normal checklist associated with
this EICAS message.
Non–Normal Checklists
Non–normal electronic checklist use is designed to follow the same philosophy as
used with paper checklists. Non–normal checklists are done by read–and–do. If a
checklist has memory steps, those steps are accomplished before accessing the
checklist.
Non–Normal Checklist Access and Checklist Icon
Annunciated non–normal checklists are accessed by pushing the checklist display
switch. Any non–normal checklist can be accessed using the NON–NORMAL
menu.
EICAS messages determine which non–normal checklist is automatically
displayed. EICAS alert messages with associated incomplete or unaccessed
checklist procedures are displayed with an icon (a white, empty box) to the left of
the message. The icon indicates checklist status. The presence or absence of the
icon indicates:
icon displayed – the checklist for the displayed message has not been
accessed, or the checklist has incomplete steps
icon not displayed – all checklist steps are complete, there is no checklist
procedure for the displayed message, or another message is displayed
whose corresponding checklist inhibits display of the icon
When pushing the checklist display switch and a single EICAS message exists, the
non–normal checklist for that condition is displayed. If multiple active EICAS
messages exist, pushing the checklist display switch displays a list showing the
non–normal checklists ready for display. This list represents the non-normal
checklist queue. If the number of checklists in the queue exceeds 10, a page
indicator is displayed to the right of the list.
The checklist queue order is similar to EICAS message priority:
•EICAS WARNING
EICAS CAUTION
February 13, 2009

Table of Contents

Related product manuals