787 Flight Crew Operations Manual
DO NOT USE FOR FLIGHT
Fuel -
Controls and Indicators
Copyright © The Boeing Company. See title page for details.
D615Z003-TBC 12.10.9
Center Tank Quantity
(amber)
FUEL IN CENTER message is displayed.
Center Tank Quantity
(amber)
Center fuel tank quantity is low. FUEL LOW
CENTER message is displayed.
Pointer
(amber)
FUEL IMBALANCE is displayed. The pointer
is displayed next to the tank with the lower
quantity.
Pointer
(white)
The crossfeed switch is ON or the balance
switch is ON and the main tank quantities differ
by more than 200 lbs (or 100 kgs). The pointer
is displayed next to the tank with the lower
quantity.
Fuel Balanced
(white)
Balanced indication. The fuel balanced
indication flashes once fuel is within 200 lbs (or
100 kgs). of balanced.
Minimum Fuel
Temperature
(temperature
displayed white)
Normal indication. Displays the lowest of three
tank temperatures.
Minimum Fuel
Temperature
(temperature
displayed as blank)
Invalid indication.
Symbol Indication Description
149.0
5.0
25.4
25.4
FUEL BALANCED
MIN FUEL TEMP
-37c
MIN FUEL TEMP
October 31, 2007