787 Flight Crew Operations Manual
DO NOT USE FOR FLIGHT
Engines, APU -
Controls and Indicators
Copyright © The Boeing Company. See title page for details.
7.10.10 D615Z003-TBC
[Option – RR engines]
Displayed (magenta) – airspeed range necessary for a windmilling in-flight start
at the current flight level or maximum flight level (whichever is less) when the
respective engine fire switch is in and:
the FUEL CONTROL switch is in CUTOFF, or
the engine N2 RPM is below idle
Cross Start Indications
[Option – GE engines]
1
In-Flight Start Envelope
EGT
1
N
188
FL 300 240-330 KTS
.21 5
EICAS DISPLAY
1
2
N
X-START
.91 1 .10 0
SECONDARY ENGINE DISPLAY