EN
21
Device description
www.bora.com
Power levels Safety shut-down after hrs:min
Level 1 Level 2 Level 3
12:00 08:24 06:00
10:00 06:24 04:00
09:00 05:12 02:30
08:00 04:12 02:00
06:00 03:18 01:30
04:00 02:12 01:00
04:00 02:12 01:00
03:00 01:48 00:45
02:00 01:18 00:30
00:05 00:05 00:05
Tab. 5.12 Safety shut-down for power levels
Warming level Safety shut-down after hrs:min
Level 1 Level 2 Level 3
12:00 08:00 04:00
Tab. 5.13 Safety shut-down for the warming level
XX
Switch the cooking zone back on if you want to put the
cooking zone back into operation.
5.6.2 Overheating protection
i
If the cooktop overheats, the power is reduced or the
cooktop is switched off completely.
The device is fitted with overheating protection. The overheating
protection can be triggered if:
XO
Cookware is heated up empty.
XO
Oil or fat is heated on high power.
XO
A hot cooking zone is switched on again after a power cut.
Whilst the overheating protection is active, one of the following
steps is taken:
XO
The activated power setting is switched back to the previous
level.
XO
The power setting P can no longer be switched on.
XO
The power level set is reduced.
XO
The cooktop switches off completely.
After a sufficient cooling period, the cooktop can be used again
in full.