System Introduction
25
1070 072 145-102 (01.07) GB
2.3 CL200 Specifications
. The Specifications as stated below apply to operation without the Me-
moryCard. Operating with the MemoryCard requires additional obser-
vation of the operating conditions issued by the manufacturer.
. The CL200 controller is a Class A device. It is designated for deploy-
ment in an industrial setting. When operated in private residences, in
business or small-industry settings, the CL200 may cause radio inter-
ference. In such case, the user will be required to introduce suitable
preventive radio interference countermeasures. Such measures inc-
lude the introduction of additional screening and filters. The user will
be required to obtain a single operating license issued by the appro-
priate national authority or approval body.
Specifications CL200
Complies w/ applicable laws/standards D EMC Directive of 9.11.1992
D EN 50081-2
D EN 61131-2
D EN 60204-1
D EN 50178
D EN 60529
Power supply NT200 power supply module, 24 VDC,
(19.2 thru 30 V)
Bridging capability, input power inter-
mittents on NT200 power supply mo-
dule, as per EN 61131-2
Class PS2
v 10 ms, repetition rate w 1 s
Current draw, from 24-V power supply
D Nominal current 1.8 A
D Minimum HW configuration:
NT200, ZE200A, 16 inputs, 16 out-
puts
typ. 220 mA
Interference emission when properly
installed in module rack
D Housing, radio interference sup-
pression as per EN 500812
Class A
D Frequency 30 thru 230 MHz;
imit. value 30 dB (mV/m) at 30 m
D Frequency 230 thru 1000 MHz;
limit value 37 dB (mV/m) at 30 m
Interference resistance when properly
installed in module rack
D high-frequency electromagnetic
fields, as per EN 61131-2
Test field strength 10 V/m
Frequency range 27 thru 500 MHz
Sweep rate 0.0015 Dec/s
D electrostatic discharge on exposed
housing components,
w/o MemoryCard
EMI resistance 4 for moisture class
RH-2
D as per EN 61131-2 D Air gap discharge 15 kV
D Contact discharge 4 kV