Module Racks
32
1070 072 145-102 (01.07) GB
3.2 Assembly
Hole for joining two module
racks w/ mounting screws
Hole for joining two module
racks w/ mounting screws
Locking foot
GG3 : 223.5
GG3K : 132
162.4
183.8
125.9
The module racks GG3 and GG3-K are suitable for installation in a control
cabinet meeting IP54 protection category requirements.
The GG3 and GG3-K module racks can be installed in two ways:
D horizontal rack installation
D vertical rack installation,
in which case the permissible operating temperature as per EN 61131-2
is reduced to between 5 and 40 _C, and only 50% of the outputs may
have a HIGH signal applied at the same time.