5.4.2 Front view with connection points
Front view
(example)
Connection
point
Stranded
wire
[mm²]
AWG Description
X4 0.25–0.5 - Encoder evaluation EC
X24 P2,
X25 P1
- - Communication sercos III / EtherCAT
S3
X31 0.75–1.5 20–14 Digital inputs/outputs
Probe input
X32 0.75–1.5 20–14 Analog inputs
X33 0.75–1.5 20–14 Voltage input (24V, 0V)
Bb relay
X49* 0.75–1.5 20–14 Safety technology L3
H1 - - Interface for control panel
* Optional connection point; the optional connection points are
marked with gray background color in the exemplary figure
Tab. 5-8: CSE02 connection points
Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P34/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Rexroth IndraDrive control sections
Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com