8.10 Analog Output
Data Unit min Typ. max
Output voltage V -10 +10
Output load, ohmic 2
Output load, capacitive nF 100
Resolution mV/incr 24
Conversion time (incl. response
time)
µs 750
250
1)
Output clock Position controller clock
Precision (in relation to the measur‐
ing range)
±0.5% with load ≥ 10 kΩ
±1% with load
≥ 2 kΩ
Short circuit protection Present
Overload protection Present
1) Applies to optional I/O extension DA
Tab. 8-37: Analog Output
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 125/143