7.10 X42, X43, Safe Motion safety technology (communication)
View Identifica‐
tion
Function
X42:
X43:
X42
X43
Connection points for connecting the HSZ01 safety zone module and the safety
zone nodes:
X42: Input
X43: Output
Connection cable Maximum total length of all cables of a safety zone: 2,500 m
Maximum length of one cable between two connection points: 100 m
Number of safety zone nodes (without HSZ01):
Maximum: 35
Minimum: 1
Ready-made cables which can be ordered:
RKB0051
Short cables to connect devices arranged side by side in the control cabinet.
Available lengths: 0.19 m; 0.25 m; 0.35 m; 0.55 m
Minimum bending radius: 4xD (= 4x6 mm = 24 mm)
Order code for a 0.55 m long cable: RKB0051/00,55
RKB0052
Long cables to connect remote communication nodes, also outside of the con‐
trol cabinet.
Available lengths: 1 m; 2 m; 5 m
Minimum bending radius: 8xD (= 8x6 mm = 48 mm)
Order code for a 5 m long cable: RKB0052/005,0
A flexible installation of the cable is not allowed.
Tab. 7-10: X42, X43
7.11 X42.1, X42.2, X43.1, X43.2, Safe Motion safety technology
(communication)
Assignment
X42.1, X43.1: Axis 1
X42.2, X43.2: Axis 2
Data
chapter 7.10 "X42, X43, Safe Motion safety technology (communication)" on
page 72
Bosch Rexroth AG DOK-INDRV*-CXX02******-PR03-EN-P72/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Optional connection points
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com