EasyManua.ls Logo

Bosch Rexroth IndraDrive CSH02 - 8.4 PB - PROFIBUS

Bosch Rexroth IndraDrive CSH02
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
sercos III
LED: Color / flashing pattern
1)
Description
Prio
2)
Off
NRT mode (no sercos communication)
3)
6
Permanently lit orange
CP0 (communication phase 0 active) 6
Flashing orange-green
CP1 (communication phase 1 active) 6
Flashing orange-green
CP2 (communication phase 2 active) 6
Flashing orange-green
CP3 (communication phase 3 active) 6
Permanently lit green
CP4 (communication phase 4 active) 6
Flashing green
Transition from Fast forward to Loopback 5
Flashing red-orange
Application error
(Sub-device/device error [C1D])
4
Flashing red-green
MST warning
4)
(S-0-1045, sercos: Device Status [S-Dev], bit15)
3
Permanently lit red
Communication error
(Sub-device/device error [C1D])
2
Flashing orange
Identification
(S-0-1044, sercos: Device Control [C-Dev], bit15)
1
Flashing red
Internal watchdog 0
1) Flashing pattern: One square corresponds to a duration of
250 ms; the arrow marks the end of a cycle; abbreviations on
the squares: GN = LED permanently lit green, OG = LED per‐
manently lit orange, RD = LED permanently lit red, -- = LED is
off
2) Display priority (1 = highest priority); the state of the highest
priority is displayed
3) NRT = None Real Time
4) MST = Master synchronization telegram
Tab. 8-20: Diagnostic LED
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 109/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Technical data - functions
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com