View Connection Signal name Function
1 TD+ Transmit, differential output A
2 TD- Transmit, differential output B
3 RD+ Receive, differential input A
4 n. c. -
5 n. c. -
6 RD- Receive, differential input B
7 n. c. -
8 n. c. -
Housing Shield connection
Properties
Standard ● Ethernet
●
Type: RJ-45, 8-pin
Compatibility 100Base-TX according to IEEE 802.3u
Recommended cable type ● According to CAT5e; type of shield ITP (Industrial Twisted Pair)
●
Ready-made cables which can be ordered:
– RKB0011
Long cables (100 m at maximum) to connect the drive system to the high‐
er-level control unit or remote communication nodes.
Minimum bending radius:
– 48.75 mm if laid flexibly
– 32.50 mm if laid permanently
Order code for a 30 m long cable: RKB0011/030,0
– RKB0013
Short cables to connect devices arranged side by side in the control cabi‐
net.
4 lengths available: 0.19 m; 0.25 m; 0.35 m; 0.55 m
Order code for a 0.55 m long cable: RKB0013/00,55
Minimum bending radius: 30.75 mm
Tab. 6-6: Function, Pin Assignment, Properties
LEDs
chapter 8.3 "ET - Multi-Ethernet" on page 104
DOK-INDRV*-CXX02******-PR03-EN-P Bosch Rexroth AG 51/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
On-board connection points
Courtesy of CMA/Flodyne/Hydradyne ▪ Motion Control ▪ Hydraulic ▪ Pneumatic ▪ Electrical ▪ Mechanical ▪ (800) 426-5480 ▪ www.cmafh.com