EasyManua.ls Logo

Bosch rexroth SE 2/C Series - Technical data; Ambient conditions

Bosch rexroth SE 2/C Series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical data 107/108
3 842 358 737/2022-08, MIT: SE 2/C-…, SE 2/R-…, Bosch Rexroth AG
16 Technical data
For dimensions, see sales catalog TS 2plus.
Maximum load/section load:
Conveyor unit SE 2/C-100: max. 100 kg / 1.0 kg/cm support surface length
Conveyor unit SE 2/C-250: max. 250 kg / 1.0 kg/cm support surface length
Conveyor unit SE 2/C-H: max. 400 kg / 2.0 kg/cm support surface length
Conveyor unit SE 2/R-300: max. 300 kg / 1.5 kg/cm support surface length
Conveyor unit SE 4/R-300: max. 300 kg / 1.5 kg/cm support surface length
Conveyor unit SE 2/R-700: max. 700 kg / 1.5 kg/cm support surface length
Conveyor unit SE 4/R-700: max. 700 kg / 1.5 kg/cm support surface length
Conveyor unit SE 2/R-H: max. 1200 kg / 2.0 kg/cm support surface length
Conveyor unit SE 2/R-V-1200: max. 1200 kg / 1.5 kg/cm support surface length
Noise emissions: < 70 dB (A)
16.1 Ambient conditions
The transfer systems have been designed for stationary use in a location
that is protected from the elements.
Operating
temperature
+5 °C to +40 °C
–5 °C to +60 °C at 20 % reduced load
Storage temperature –25 °C to +70 °C
Relative humidity 5% to 85%
Air pressure > 84 kPa, corresponds to an installation
altitude < 1400 m above sea level
Max. load capacity of fl oor: 1000 kg/m
2
At installation altitudes > 1400 m, the load values of the electric drives are
reduced by 15%.
The area should be kept free of mold, fungus, rodents and other vermin.
Do not install or operate in the immediate vicinity of industrial equipment
producing chemical emissions.
Do not install or operate near sources of sand or dust.
Do not install or operate in areas that are regularly subjected to
high-energy forces caused, for example, by presses or heavy machinery.
Resistant to many media that are commonly found in manufacturing,
such as water, mineral oil, grease, and detergents. Contact your Rexroth
representative if you have any doubts about resistance to specifi c
chemicals, such as test oil, doped oils, corrosive detergents, solvents or
brake fl uid.
Avoid prolonged contact with highly reactive acidic or alkaline materials.
ENGLISH

Table of Contents