6-4
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Area Programming
Single Button Part Off
This option allows users to disarm from Part Mode or Part Mode 2
simply by pressing the OFF key. This function will only work if there
are no alarms in eect, and the entry timer is not running.
Areas > Properties >
Input Options
MENU 2-1-2
1 Non Sequential Handover (Entry Path) Y
2 Pulse Count Handover Allowed Y
3 Senior Watch N
4 Reset Smoke On Arming Y
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
The above options are programmable per area.
1) Enter [MENU] + [2] + [1] + [2] and select the area from the list
then press [OK].
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Non Sequential
Pulse Count H/Over
Senior Watch
Press
 OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Non Sequential Handover
With Non-Sequential entry path you can trigger handover zones in
any order provided that an entry delay zone was triggered rst.
If this option is not programmed, handover zones must be triggered
in numerical sequence provided that an entry delay zone was
triggered rst.
If a handover zone is triggered before an entry delay zone is triggered
an instant alarm will occur.
Pulse Count Handover Allowed
This option allows zones from the same area that have both pulse
count and pulse count time programmed the ability to hand over
pulses to other pulse count zones during their respective pulse count
time. Only zones that have an active pulse count time can accept
pulse count handover from another zone.
Burglary delay zones can only handover pulses to other burglary
delay zones. Burglary instant and/or handover zones can handover
pulses to other burglary instant and/or handover zones. 24 hour
non-re zone types can only handover pulses to other 24 hour non
re zones. A 24-hour re zone can only handover pulses to another
24-hour re zone.
Senior Watch
This option requires at least one burglary zone in the corresponding
area to be faulted and restored during the senior watch time. If no
burglary zone has register during the senior watch time, the keypad
will sound an alarm.
To warn the user that senior watch time is about to expire, the keypad
will sound the auto arm pre-alert time (if programmed) prior to
sounding the alarm. See MENU 7-2-6 — Senior Watch Time.
This feature is not applicable when the corresponding area is turned
All On.
An output (Output Event Type 51) can be programmed to operate as
follow Senior Watch if required.
Reset Smoke On Arming
This option when set, will trigger any output that is
programmed as event type 49 - Smoke Sensor GND to
operate on the next arming cycle, therefore resetting the
connected smoke sensors each time the area is armed.
If this option is not set then a manual reset will need to be
performed via MENU 3-0-5.
Areas > Properties >
Output Options
MENU 2-1-3
1 Arm/Disarm Speaker Beeps Via RF Keyfob Y
2 Arm/Disarm Speaker Beeps Via Keyswitch Y
3 Siren / Strobe When Part On Allowed Y
4 Alarm On PIN Retry Violations Y
5 Alarm On Exit Error N
6 Alarm On Keyswitch Tamper ( Only If System Armed) Y
7 Reserved N
8 Reserved N
The above options are programmable per area.
1) Enter [MENU] + [2] + [1] + [3] and select the area from the list
then press [OK].
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
SPK Beeps Keyfob
SPK Beeps Key/SW
SPK Strobe In Part ON
Press
 OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Arm/Disarm Speaker Beeps Via RF Key Fob
This option allows audible beeps via the speaker output to verify to
the user that they have successfully turned the area On or O using
the RF keyfob. The speaker output will sound One beep for O, two
beeps for On and three beeps for Part On.
Arm/Disarm Speaker Beeps Via Keyswitch
This option allows audible beeps via the speaker output to verify to
the user that they have successfully turned the area On or O using
a Keyswitch. The speaker output will sound One beep for O, two
beeps for On.
Siren / Strobe When Part On Allowed
This option allows the strobe and audible alarms to operate when the
system is turned Part On or Part 2 On mode.