6-5
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Area Programming
Alarm On PIN Retry Violations
When the PIN Retry Count as programmed in MENU 1-5-1 is reached
an audible alarm will occur.
Alarm On Exit Error
This option allows you to sound an alarm when an exit error occurs.
An exit error occurs when an entry/exit delay zone becomes unsealled
during exit delay time and remains unsealled at the end of exit delay
time. If this happens, the entry delay will start. If the area is not
turned o (disarmed) before the entry delay time expires an alarm will
occur.
i
Note
Software Version 1.02 and higher has been corrected to send exit
error reports via CID format. Previous versions failed to send exit
error reports in CID, however, reporting in SIA format was not
eected.
Alarm On Keyswitch Tamper
This option allows you to sound an alarm when a tamper condition
occurs on a zone programmed as a Keyswitch Zone.
Refer to Menu 3-1-1 — Zone Type in Section 8 - Input Programming
for information on programming zones to be a keyswitch input.
Areas > Properties >
Reporting Options
MENU 2-1-4
1 Report PIN Retry Y
2 Report Exit Error Y
3 Smart Lockout N
4 Reserved N
5 Cancel Reports Y
6 Reserved N
7 Open / Close Reports For Part On N
8 Open / Close Reports Only After Alarm N
The above options are programmable per area.
1) Enter [MENU] + [2] + [1] + [4] and select the area from the list
then press [OK].
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Report PIN Retry
Report Exit Error
Smart Lockout
Press
 OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Report PIN Retry
When the PIN Retry Count as programmed in Menu 1-5-1 is reached a
Wrong Code Entry alarm report will be sent to the Control Room.
Report Exit Error
This option allows the system to report and Exit Error Alarm.
An exit error occurs when an entry/exit delay zone becomes unsealled
during exit delay time and remains unsealled at the end of exit delay
time. If this happens, the entry delay will start. If the area is not
turned o (disarmed) before the entry delay time expires an Exit Error
alarm report will be sent.
Smart Lockout
Smart lockout allows and previously locked zones to reactivate during
the siren run time when a new alarm event occurs.
Cancel Reports
When set, a Cancel report will be sent if a user disarms the area before
the siren timer expires.
i
Note
Software Version 1.07 and higher has been corrected to send the
current user ID with the cancel report. In previous software, the
user ID that was sent as part of the cancel report was from the
previous arm/disarm cycle.
Open/Close Reports For Part On
When set, the panel will Send Open or Close reports when the system
is armed in Part On mode.
i
Note
Software Version 1.07 and higher has been corrected to only
send open and close reports for Part On/O when this option has
been programmed. Previous software would still send a closing
report even is this option was not programmed whn the system
had send a previous ‘Open’ report.
Open/Close Reports Only After Alarm
When set, the panel will send a single Open / Close report if a
previous alarm has occured. This report will be sent for all users
regardless of whether or not they have been programmed to send
Open/Close reports.
Areas > Properties >
Strobe Trigger
MENU 2-1-5
1 Audible Burglary Alarm Y
2 Silent Burglary Alarm N
3 Fire Alarm Y
4 Arm / Disarm Flash Via RF Keyfob N
5
Arm / Disarm Flash Via Keyswitch or PGM Input
N
6 Reserved N
7 24-Hour Alarm Y
8 Reserved N
Programming any of these options allow the strobe output to
operate when the corresponding event occurs. The strobe light
must be connected to an output programmed as a Event Type
48 for it to operate. See Section 8 output Programming for
more Information on output event types.
1) Enter [MENU] + [2] + [1] + [5] and select the area from the list
then press [OK].
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Audible Burglary
Silent Burglary
Fire Alarm
Press
 OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Audible Burglary Alarm
When selected, the panel will activate the strobe output when an
audible burglary zone has triggered an alarm.