6-6
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Area Programming
Silent Burglary Alarm
When selected, the panel will activate the strobe output when a silent
burglary zone has triggered an alarm.
Fire Alarm
When selected, the panel will activate the strobe output when a zone
programmed as re (audible or silent) has triggered an alarm.
Arm/Disarm Flash Via RF Keyfob
When slected, the panel will activate the strobe output for six seconds
when a user turns the area on via an RF Key fob. This provides silent
feedback to the user that the signal has been received.
Arm/Disarm Flash Via Keyswitch or PGM Input
When selected, the panel will activate the strobe output for six
seconds when a user turns the area on via a Keyswitch Input or the
Programmable Input. This provides silent feedback to the user that
the signal has been received.
24-Hour Alarm
When selected, the panel will activate the strobe output when a zone
programmed as 24-hour (audible or silent) has registered an alarm.
Zones programmed as 24-Hour Hold-Up are not included.
Software versions eariler than 1.07 would not operate the strobe
when a 24 hour panic zone is faulted.
ARE A R EPO RT I NG
Areas > Reporting >
Account Dest 1
MENU 2-2-0
0 0 0 0 0 0 0 0 0 0
The area account number identies which control panel is
reporting to the security company’s base station receiver. Each
destination can have a dierent account number programmed.
The number should be entered from left to right with trailing
zeros.
1) Enter [MENU] + [2] + [2] + [0] and select the area from the list
then press [OK].
2) Using the numeric keys, enter the new account number. Use
the up and down arrows to select special characters BCDEF.
Account Dest 1 A001
1604000000
Press 0-9 OK to SAVE
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
Areas > Reporting >
Account Dest 2 MENU 2-2-1
0 0 0 0 0 0 0 0 0 0
The area account number identies which control panel is
reporting to the security company’s base station receiver. Each
destination can have a dierent account number programmed.
The number should be entered from left to right with trailing
zeros.
1) Enter [MENU] + [2] + [2] + [1] and select the area from the list
then press [OK].
2) Using the numeric keys, enter the new account number. Use
the up and down arrows to select special characters BCDEF.
Account Dest 2 A001
1604000000
Press 0-9 OK to SAVE
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
Areas > Reporting >
Open / Close Route
MENU 2-2-2
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs the destination for open and close reports.
Only one option can be programmed in this menu.
1) Enter [MENU] + [2] + [2] + [2] and select the area from the list
then press [OK].
2) Use the numeric keys 0-9 or the up and down arrow keys to
select the desired option.
Open/Close Route A001
01 - Dest 1 + Log
Press 0-9 OK to SAVE
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
ARE A T EST I NG
Areas > Area Testing >
Area Watch
MENU 2-9-0
0 1 2
(*** System Wide Parameter ***)
WEEKS
This menu programs the number of weeks (001 – 255 weeks /
000 = disabled) an area can remain disarmed before registering
an ‘Inactivity Interval’ report. A restore signal will be sent when
the area is next armed and the exit time expires.
1) Enter [MENU] + [2] + [9] + [0] . The keypad will display the
current number of weeks programmed for area watch.
Area Watch
012 Weeks