7-4
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Input Programming
ZONE DE FAU LT TA B LE
The table below lists the default values for all zone parameters in the Solution 16
plus
. By default, zones 5 to 16 are set as Instant zones.
Zones marked as Not Used do not require EOL resistors to be tted.
Programming Option Zone 1 Zone 2 Zone 3 Zone 4 Zones 5 to 16
Zone Name Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 - Zone 16
Zone Type 1 = Delay 1 5 = Handover 5 = Handover 5 = Handover 3 = Instant
Area Assignment 1 1 1 1 1
Pulse Count 0 0 0 0 0
Pulse Count Time (Sec’s) 120 120 120 120 120
Access Group 0 0 0 0 0
Report Route 2 2 2 2 2
Reporting Options
Lockout Dialler Y Y Y Y Y
Report Alarm Y Y Y Y Y
Report Alarm Restore Y Y Y Y Y
Report Trouble Y Y Y Y Y
Report Trouble Restore Y Y Y Y Y
Report Bypass Y Y Y Y Y
Report Bypass Restore Y Y Y Y Y
Delay Report N N N N N
Zone Options
Lockout Siren Y Y Y Y Y
Silent Alarm N N N N N
Inverted Seal N N N N N
Bypass Allowed Y Y Y Y Y
Sensor Watch N N N N N
Armed When Part On Y Y Y Y Y
Reserved N N N N N
Test On Exit N Y Y Y Y
Table 21: Zone Defaults
ZONE PR O PE R TI ES
Inputs > Zone Properties >
Zone Name
-
MENU 3-1-0
Z o n e 1 N a m e
This menu allows you to program the name for each zone. Zone
names can be up to 16 characters long.
1) Enter [MENU] + [3] + [1] + [0] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK].
2) User the arrow and number keys to move and change text.
When the Zone Name is complete, press [OK]. At any time you
can press the [OFF] key to clear the text from the current cursor
position to the end of the line.
Zone Name Zn001
Zone 1 Name
Press OK to SAVE
See Alpha Text Programming in Section 4 - Programming
Overview for further detail on entering alpha text.
Inputs > Zone Properties >
Zone Type
MENU 3-1-1
1
This menu allows you to congure the zone type or behaviour
for every zone in the system. Each zone should be assigned to a
Zone Type that denes the way in which the panel will respond
when an alarm is triggered on that zone. Refer to the table and
descriptions below for the available Zone Type selections.
Zone Types
0 = Zone Not Used
1 = Burglary Delay 1 (Entry Timer 1)
2 = Burglary Delay 2 (Entry Timer 2)
3 = Burglary Instant 1 (With Exit Delay)
4 = Burglary Instant 2 (No Exit Delay)
5 = Burglary Handover
6 = Burglary 24-Hour
7 = Tamper 24-Hour
8 = Hold Up 24-Hour (Silent & Invisible)
9 = Medical 24-Hour
10 = Panic 24-Hour
11 = Fire 24-Hour
12 = Reserved
13 = Keyswitch Zone
14 = Display Only
15 = 24-Hour Non Burglary
Table 22: Zone Types