Loading...
7-7
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Input Programming
When a user who belongs to Access Group 5 presents their
token to the reader that is assigned to Access Group 5, the
assigned output will operate releasing the door strike.
A reader can belong not only to a Access Group but also to an
Area if arming and disarming is required from the reader.
If a user presents their token to an reader that has an area
assigned, then the user Access Group and Area Permissions are
both checked. If the area is armed and the user belongs to the
same area as the Reader and the same Access Group, the system
will disarm and allow access.
If the user does not belong to the same area as the reader but
the Access Groups match, then door access will only be available
to that user if the area is disarmed.
When using the same reader for door access as well as arming,
you need to select the badging option MENU 1-6-3 Reader
Options. Badging requires that you present your token 3 times
in succession within 5 seconds to arm the system.
Inputs > Zone Properties >
Access Group
MENU 3-1-5
0
1) Press [MENU] + [3] + [1] + [5] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the current Access Group setting.
Access Group Zn001
00 - No Access Group
Press  0-9 OK to SAVE
2) Use the up and down arrows to select the Access Group that
you want to assign the zone to.
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
Inputs > Zone Properties >
Report Route
MENU 3-1-6
0 = Report Events To Log Only 1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails +Log
This menu sets the Zone Report Route or Report Destination for
each individual zone in the system. All events such as alarms
and troubles for each zone will be reported according to this
menu setting. Each zone can only be assigned to one report
route from the list above.
1) Press [MENU] + [3] + [1] + [6] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the current Zone Report Route.
Report Route Zn001
01 - Dest 1 + Log
Press 0-9 OK to SAVE
2) Use the up and down arrows to select the Report Route that
you want to assign the zone to.
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
i
Note
At factory default all Zones are set to report to Destination 1 and
the System Log. See the Zone Default Table for more information
on Zone default settings.
Inputs > Zone Properties >
Report Options
MENU 3-1-7
1 Lockout Dialler Y
2 Report Alarm Y
3 Report Trouble Y
4 Report Bypass Y
5 Reserved N
6 Reserved N
7 Report Restores Y
8 Delay Report N
The above options are programmable per zone.
1) Press [MENU] + [3] + [1] + [7] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the Report Options for the currently
selected zone.
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Lockout Dialler
Report Alarm
Report Troubles
Press  OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Lockout Dialler
Setting this option will enable Dialler Lockout functionality for
the respective zone(s). All zones in the system can be individually
programmed for Dialler Lockout.
When enabled the zone will be allowed to transmit alarm reports
each time it is triggered provided that the Swinger Dialler count has
not been reached. If the zone is triggered and the Swinger Dialler
count has been reached then the zone will become locked out and no
further reports will be sent for that zone. Dialler lockout will be reset
on the next arming cycle.
See MENU 5-4-5 — Swinger Dialler to set the number of times a zone
is allowed to trigger before being locked out.