7-8
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Input Programming
Report Alarm
Setting this option will enable the system to Report Alarm events
for the respective zone. All zones in the system can be individually
programmed to report alarms.
Report Trouble
Setting this option will enable the system to Report Trouble events
for the respective zone. A Trouble report will be sent if the zone is
left unsealled at the end of exit time. All zones in the system can be
individually programmed to report trouble events.
Report Bypass
Setting this option will enable the system to Report Zone Bypass
events for the respective zone. A Bypass report will be sent at the end
of exit time for zones which have been manually bypassed. All zones
in the system can be individually programmed to report Zone Bypass
events.
i
Note
Software Version 1.02 and higher now allows bypass reports for
non-burglary zones including keyswitch, Display Only and 24hr
Non Burglary zones.
Report Restores
Setting this option allows the system to send Restore reports for
zones that have already sent a previous alarm or trouble report on the
same arming cycle.
1) Burglary Zone alarms and troubles restore when the zone
reseals or the area is disarmed.
2) 24hr Zone alarms and troubles restore when the zone reseals.
3) Bypassed Zone restore when the area is disarmed.
Delay Report
Setting this option will cause the system to delay alarm reports for
the selected zone. This option can be enabled to allow a user to enter
their PIN and disable the report in case they have caused a false alarm.
If a PIN is not entered within the delay time, the system will trigger the
sirens and send the report as normal.
See MENU 5-4-6 — Burg Report Delay and MENU 5-4-7 — Fire Report
Delay to set the delay time.
If a PIN code is entered after the delay time has expired, and the sirens
are still sounding, the system will send the Alarm report followed by a
Cancel report.
i
Note
Software Version 1.02 and higher corrected. Previous versions
would ignore the delay time and report events immediateley.
Inputs > Zone Properties >
Zone Options
MENU 3-1-8
1 Lockout Siren Y
2 Silent Alarm N
3 Inverted Seal N
4 Bypass Allowed Y
5 Sensor Watch N
6 Armed When in Part Mode 1 Y
7 Reserved N
8 Test On Exit Y
The above options are programmable per zone.
1) Press [MENU] + [3] + [1] + [8] and use the up and down arrows
to highlight the Zone in the list then press [OK]. Alternatively,
you can enter the zone number directly and press [OK]. The
keypad will display the Zone Options for the currently selected
zone.
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
Lockout Siren
Silent Alarm
Inverted Seal
Press  OK ON OFF MENU
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Lockout Siren
Setting this option will enable Siren Lockout functionality for the
respective zone(s). All zones in the system can be individually
programmed for Siren Lockout.
When enabled the respective zone will be allowed to cause the
sirens to sound each time a new alarm is triggered provided that the
Swinger Siren count has not been reached. If the zone is triggered and
the Swinger Siren count has been reached then the siren will become
locked out for that zone and no further siren activations will occur
from that zone. Only zones which have been locked out are prevented
from triggering the sirens.
Siren lockout will be reset on the next arming cycle.
See MENU 7-4-3 — Swinger Siren to set the shutdown count.
Silent Alarm
Setting this option will set the correspondiing zone to become a silent
zone. Audible alarm outputs will not sound when a silent zone is
triggered.
Inverted Seal
Setting this option allows a normally-open sensor or device to operate
as a normally-closed device by reversing the open/closed state of the
zone loop. (eg. When the zone loop is open, the system will register
the zone loop as closed or normal.)
Bypass Allowed
Setting this option allows users with the appropriate access level to
manually bypass this zone eectively removing it from the area for
the current arming cycle. All zone types including 24hour zones can
be bypassed if this option is selected. Bypassed zones will be reset
when the area is turned o or disarmed.