10-6
Bosch Security Systems 05/10 BLCC100I
Solution 16
plus
Installation Manual Device Programming
within the supervision time period.
The panel will send a Missing report to the base station for any
RF device that fails to report within the supervision time.
1) Press [MENU] + [6] + [2] + [1]. The keypad will display the
current RF supervision time.
Supervision Time P001
024 Hours
Press 0-9 OK to SAVE
2) Using the numeric keys, enter the number of hours for the RF
supervision time. Valid times are 0 - 255 hours, 0 = No
Supervision.
3) Press [OK] to save and exit or press [MENU] to exit without
saving.
Device > RF Devices >
RF Device Options
MENU 6-2-2
1 Display RF Tamper Y
2 Report RF Tamper Y
3 Report RF Low Battery Y
4 Report Lost RF Device Y
5 Open Zone On Lost RF Y
6 Audible Keyfob Panic Y
7 Report Keyfob Panic Y
8 Keyfob Function 1 Key = Part On Y
This menu option allows you to congure various options and
functions for RF devices connected to the system.
1) Press [MENU] + [6] + [2] + [2]. The keypad will display the
current RF Device Options.
Display RF Tamper
Report RF Tamper
Report RF Low Battery
Press  OK ON OFF MENU
2) Use the up and down arrow keys to highlight the option then
press the [ON] key to enable or the [OFF] key to disable.
3) Repeat Step 2 until all options are programmed as required,
then press [OK] to save and exit or press [MENU] to exit
without saving.
Display RF Device Tamper
Setting this option will cause the keypad to display the RF zone when
a tamper condition occurs.
Report RF Device Tamper
Setting this option will cause the panel to send an RF Device Faulted
report to the base station when the devices tamper curcuit is tripped.
A restore report will be sent when the tamper circuit is resealled.
Report RF Device Low Battery
Setting this option will cause the panel to send a report to the base
station when the RF device signals to the panel that it has a low
battery condition.
Report RF Device Missing
Setting this option will cause the panel to send a report to the base
station if the panel detects that an RF device is missing.
Open Zone On RF Device Missing
Setting this option will cause the panel to show a zone fault on the
keypad for any RF devices that are missing
Audible RF Key Fob Panic
Setting this option allows users who have RF keyfobs to trigger an
audible panic alarm via the keyfob.
Report RF Keyfob Panic
Setting this option will cause the panel to send a Panic report to the
base station when a panic alarm has been initiated via a key fob.
i
Note
New - Software Version 1.05 and higher allows the RF keyfob
panic to report low battery by user.
RF Keyfob Function Key 1 = Part On
Setting this option will allow keyfob users to arm an area or all areas
of the system using function key 1 on the keyfob.
Devices > RF Devices >
Add RF Keypad
MENU 6-2-3
Reserved for future use.
Delete RF Keypad
MENU 6-2-4
Reserved for future use.
View RF I.D.
MENU 6-2-5
This command allows you to trap and view a transmitters I.D.
number when it has been forgotten or it is no longer legible
on the transmitter label. The device being tested must be
compatible with the RF receiver tted to the panel.
1) Press [MENU] + [6] + [2] + [5]. The system will then begin
waiting for a valid trigger signal.
Waiting for Trigger!
Press OK or MENU
2) Trigger the transmitter by pressing any button on the keyfob
or by triggering the tamper switch on any sensor.