The following example displays the error events that sysmon has recorded for the fabric adaptor 0.
Brocade# show sysmon counters fa error 0
Sysmon error detected on: SLOT 1, FA 0(number of times)
****PUMA Device 0 VOQUnit0 error detect
Set 0 EnQ Drop detect = 0
Set 1 EnQ Drop detect = 0
Set 2 EnQ Drop detect = 0
Set 3 EnQ Drop detect = 0
tail drop detect = 0 filter drop detect = 0, ecc drop detect = 0
****PUMA Device 0 VOQUnit1 error detect
Set 0 EnQ Drop detect = 0
Set 1 EnQ Drop detect = 0
Set 2 EnQ Drop detect = 0
Set 3 EnQ Drop detect = 0
tail drop detect = 0 filter drop detect = 0, ecc drop detect = 0
****PUMA Device 0 CRX error detect
CRC detect = 0, Lost SOP.EOP detect = 0, no egress Buf detect = 0
fifo full detect = 0, UC congest detect = 0, MC congest detect = 0
bad buf alloc detect = 0, e2e drop detect = 0
The following example shows the crossbar errors for the switch fabric module 0.
Brocade# show sysmon counters xbar error 0
Sysmon SFM 1 xbar 0 HG.link Rx error detected (number of times)
HG.link BadLen BadHeader ReformatErr
0 0 0 0
1 0 0 0
2 0 1 0
3 0 0 0
4 0 0 0
5 0 0 0
6 0 0 0
7 0 0 0
8 0 0 0
9 0 0 0
10 0 0 0
11 0 0 0
The following example displays the cross bar link errors for the SFM module 0.
Brocade# show sysmon counters xbar link 0
Sysmon SFM 0 xbar 1 HG.link NO-SYNC detected (number of times)
HG.link NO-SYNC
0 0
1 0
2 0
3 0
4 0
5 1757
6 0
7 0
8 0
9 0
10 0
11 0
The following example displays the error counter for the specified packet processor 0.
Brocade# show sysmon counter pp error 0
Sysmon error detected on: SLOT 1, PP 0(number of times)
****PUMA Device 0 Buffer SRAM error detect
Ingress buffer error detect = 0
Egress buffer error detect = 1
****PUMA Device 0 Control SRAM error detect
CSU : Parity error detect = 0, ECC error detect = 0
LPM0: Parity error detect = 0, ECC error detect = 0
LPM1: Parity error detect = 0, ECC error detect = 0
LPM2: Parity error detect = 0, ECC error detect = 0
LPM3: Parity error detect = 0, ECC error detect = 0
System Monitoring
280 FastIron Ethernet Switch Administration Guide
53-1003625-01

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems FastIron and is the answer not in the manual?

Brocade Communications Systems FastIron Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelFastIron
CategorySwitch
LanguageEnglish

Related product manuals